Skip to content
OpenCDD
classITEM_CLASSv2rev 12025-06-10IEC 60050-441: 1984, 441-15-02

Main circuit (of a switching device)

0112/2///62683#ACC014

all the conductive parts of a switching device included in the circuit which it is designed to close or open

Hierarchy#

Higher level classes2#

Declared properties79#

79 / 79
ACE401number of polesINT_TYPE

number of electrically separated conducting paths of the main circuit of a switching device

number of contacts included in the main circuit of a mechanical switching device, intended to carry, in the closed position, the current of the main circuit, for which the force for opening the contacts is provided by an electromagnet

number of contacts included in the main circuit of a mechanical switching device, intended to carry, in the closed position, the current of the main circuit, for which the force for closing the contacts is provided by an electromagnet

value of power of the load that the switching device is intended to control under the conditions of utilization category AC-6b at a rated operational voltage of 400 V a.c.

value of power of the load that the switching device is intended to control under the conditions of utilization category DC-1 at a rated operational voltage of 440 V d.c.

value of power of the load that the switching device is intended to control under the conditions of utilization category DC-3 at a rated operational voltage of 440 V d.c.

value of power of the load that the switching device is intended to control under the conditions of utilization category DC-5 at a rated operational voltage of 440 V d.c.

value of power of the load that the switching device is intended to control under the conditions of utilization category AC-3 at a rated operational voltage of 230 V a.c.

value of power of the load that the switching device is intended to control under the conditions of utilization category AC-3 at a rated operational voltage of 400 V a.c.

value of power of the three-phase motor load that the switching device is intended to control under the specified conditions at a rated operational voltage of 460 V 60 Hz

value of power of the three-phase motor load that the switching device is intended to control under the specified conditions at a rated operational voltage of 575 V 60 Hz

ACE424rated currentLEVEL(MAX) OF REAL_MEASURE_TYPE

maximum uninterrupted current equal to the conventional free-air thermal current (lth)

value of current at which the switching device is intended to operate, under the conditions of utilization category DC-1, at a rated operational voltage of 440 V d.c.

ACE426rated operational current, DC-22REAL_MEASURE_TYPE

value of current at which the switching device is intended to operate, under the conditions of utilization category DC-22

value of current at which the switching device is intended to operate, under the conditions of utilization category DC-3, at a rated operational voltage of 440 V d.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category DC-5, at a rated operational voltage of 440 V d.c.

ACE429rated operational current, 400 VREAL_MEASURE_TYPE

value of current at which the switching device is intended to operate, at a rated operational voltage of 400 V a.c.

ACE430rated operational current, 40 °CREAL_MEASURE_TYPE

value of current at which the switching device is intended to operate, under the specified conditions, at the ambient temperature of 40 °C

value of current at which the switching device is intended to operate, under the conditions of utilization category AC-1, at a rated operational voltage of 400 V a.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category AC-22, at a rated operational voltage of 400 V a.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category AC-1, at a rated operational voltage of 230 V a.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category AC-3, at a rated operational voltage of 400 V a.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category AC-23, at a rated operational voltage of 400 V a.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category AC-7a, at a rated operational voltage of 230 V a.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category AC-7b, at a rated operational voltage of 230 V a.c.

ACE438conventional free air thermal currentLEVEL(MAX) OF REAL_MEASURE_TYPE

maximum current carried continuously by unenclosed equipment in free air without the temperature rise of the various parts exceeding the limits specified

current stated by the manufacturer used for the temperature-rise tests of the equipment when mounted in a specified enclosure

ACE440ambient air temperatureLEVEL(MIN,MAX) OF REAL_MEASURE_TYPE

operating temperature limits, determined under prescribed conditions, of the air surrounding the complete switching device

value of current at which the switching device is intended to operate, under the conditions of utilization category AC-3, at a rated operational voltage of 230 V a.c.

value of power of the single-phase motor load that the switching device is intended to control under the specified conditions at a rated operational voltage of 120 V 60 Hz

ACE444rated voltageLEVEL(MAX) OF INT_MEASURE_TYPE

voltage assigned by the manufacturer for a specified operating condition of an accessory

lowest number of isolated sets of contacts that represent either normally open, normally closed, change over or cross-over function for which the device is intended

greatest number of isolated sets of contacts that represent either normally open, normally closed, change over or cross-over function for which the device is intended

ACE449step angleENUM_STRING_TYPE

number of degrees between each defined position of the device

ACE451signal indicatorENUM_BOOLEAN_TYPE

device associated with a switch to indicate the circuit state visually

code composed of one or more letters: The breaking range followed by the utilization category, and if needed, the time delay class EXAMPLE: gG, aM, gN class J ,gN class CC

ACE453fuse systemSTRING_TYPE

family of fuses following the same physical design principles with respect to the shape of the fuse-links, type of contact, etc. EXAMPLE: NH, BS, NF, H

ACE454size of the fuse-linkSTRING_TYPE

specified set of dimensions of fuses within a fuse system, each individual size covering a given range of rated currents for which the specified dimensions of the fuses remain unchanged EXAMPLE: 00, 10 x 38 mm, 0,405 x 1,5 in

ACE455rated operational voltageLEVEL(MIN,MAX) OF INT_MEASURE_TYPE

range of voltage combined with a rated operational current intended to be switched by the device under specified conditions

ACE456with OFF-positionENUM_BOOLEAN_TYPE

availability of a defined position in which all contacts are open

ACE459rated operational voltage, DC-22LEVEL(MAX) OF INT_MEASURE_TYPE

maximum value of the DC voltage at which the switching device is intended to operate under the condition of the utilisation category DC-22

ACE461return to OFF-positionENUM_BOOLEAN_TYPE

availability of at least one defined position in which the device returns to a position in which all contacts are open

ACE463category of operating cyclesENUM_STRING_TYPE

additional letter to the utilisation category code giving the distinction between frequent (A) and infrequent operation (B)

value of power of the load that the switching device is intended to control under the conditions of utilization category AC-6b at a rated operational voltage of 230 V a.c.

value of power of the load that the switching device is intended to control under the conditions of utilization category DC-1 at a rated operational voltage of 220 V d.c.

value of power of the load that the switching device is intended to control under the conditions of utilization category DC-5 at a rated operational voltage of 220 V d.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category DC-1, at a rated operational voltage of 220 V d.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category DC-3, at a rated operational voltage of 220 V d.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category DC-5, at a rated operational voltage of 220 V d.c.

value of power of the load that the switching device is intended to control under the conditions of utilization category DC-3 at a rated operational voltage of 220 V d.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category AC-21, at a rated operational voltage of 400 V a.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category AC-21, at a rated operational voltage of 690 V a.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category AC-22, at a rated operational voltage of 690 V a.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category AC-23, at a rated operational voltage of 690 V a.c.

ACE475rated operational voltage, AC-22LEVEL(MAX) OF INT_MEASURE_TYPE

maximum value of the AC voltage at which the switching device is intended to operate under the condition of the utilisation category AC-22

value of current at which the switching device is intended to operate, under the conditions of utilization category AC-21, at a rated operational voltage of 230 V a.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category AC-22, at a rated operational voltage of 230 V a.c.

value of current at which the switching device is intended to operate, under the conditions of utilization category AC-23, at a rated operational voltage of 230 V a.c.

ACE479rated operational current, DC-21REAL_MEASURE_TYPE

value of current at which the switching device is intended to operate, under the conditions of utilization category DC-21

ACE480rated operational voltage, DC-21LEVEL(MAX) OF REAL_MEASURE_TYPE

maximum value of the DC voltage at which the switching device is intended to operate under the condition of the utilisation category DC-21

ACE481rated operational current, DC-23REAL_MEASURE_TYPE

value of current at which the switching device is intended to operate, under the conditions of utilization category DC-23

ACE482rated operational voltage, DC-23LEVEL(MAX) OF REAL_MEASURE_TYPE

maximum value of the d.c. voltage at which the switching device is intended to operate under the condition of the utilisation category DC-23

ACE483contact sequenceENUM_STRING_TYPE

relation between the different operator positions versus the status of the association of contact sets in series or parallel operations

ACE739thermal memoryENUM_BOOLEAN_TYPE

ability of an overload protection for which the thermal time/current characteristic is not reset after the interruption of the current

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Source document
IEC 60050-441: 1984, 441-15-02
Version
2
Revision
1
Status
Standard
Publisher
IEC
Published in
IEC 62683DB
Responsible committee
IEC TC 121
Change request
C00136
Dates
  • Original: 2011-03-04
  • Current version: 2025-06-10
  • Current revision: 2025-06-10

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (35 keys from source .xls) — click to expand
C002
C00136
C011
IEC
C012
IEC 62683DB
C016
Standard
C017.de
1
C017.fr
1
C017.zh
1
C018.de
2017-06-15
C018.fr
2024-09-04
C018.zh
2017-09-26
C019.de
DKE, Jürgen Schütz
C019.fr
IEC 121A/WG 17
C019.zh
SAC, Li Hui
MDC_P001_5
0112/2///62683#ACC014
MDC_P002_1
2
MDC_P002_2
1
MDC_P003_0
2025-06-04
MDC_P003_1
2011-03-04
MDC_P003_2
2025-06-10
MDC_P003_3
2025-06-10
MDC_P004.de
Hauptstromkreis (eines Schaltgeräts)
MDC_P004.en
Main circuit (of a switching device)
MDC_P004.fr
Circuit principal (d'un appareil de connexion)
MDC_P004.zh
(开关电器的)主电路
MDC_P006_1
IEC 60050-441: 1984, 441-15-02
MDC_P006.de
alle leitfähigen Teile eines Schaltgeräts, die zum Stromkreis gehören, der ein- und ausgeschaltet werden soll
MDC_P006.en
all the conductive parts of a switching device included in the circuit which it is designed to close or open
MDC_P006.fr
ensemble des pièces conductrices d'un appareil de connexion insérées dans le circuit qu'il a pour fonction de fermer ou d'ouvrir
MDC_P006.zh
用于闭合和断开电路的开关电器的所有导电部件。
MDC_P010
0112/2///62683#ACC010
MDC_P011
ITEM_CLASS
MDC_P012
IEC TC 121
MDC_P014
{0112/2///62683#ACE401,0112/2///62683#ACE424,0112/2///62683#ACE457,0112/2///62683#ACE460,0112/2///62683#ACE440,0112/2///62683#ACE455,0112/2///62683#ACE476,0112/2///62683#ACE472,0112/2///62683#ACE477,0112/2///62683#ACE432,0112/2///62683#ACE473,0112/2///62683#ACE475,0112/2///62683#ACE478,0112/2///62683#ACE435,0112/2///62683#ACE474,0112/2///62683#ACE479,0112/2///62683#ACE480,0112/2///62683#ACE426,0112/2///62683#ACE459,0112/2///62683#ACE481,0112/2///62683#ACE482,0112/2///62683#ACE463,0112/2///62683#ACE413,0112/2///62683#ACE418,0112/2///62683#ACE419,0112/2///62683#ACE443,0112/2///62683#ACE439,0112/2///62683#ACE410,0112/2///62683#ACE453,0112/2///62683#ACE452,0112/2///62683#ACE454,0112/2///62683#ACE438,0112/2///62683#ACE412,0112/2///62683#ACE429,0112/2///62683#ACE434,0112/2///62683#ACE430,0112/2///62683#ACE416,0112/2///62683#ACE417,0112/2///62683#ACE420,0112/2///62683#ACE421,0112/2///62683#ACE414,0112/2///62683#ACE415,0112/2///62683#ACE422,0112/2///62683#ACE423,0112/2///62683#ACE403,0112/2///62683#ACE404,0112/2///62683#ACE442,0112/2///62683#ACE431,0112/2///62683#ACE433,0112/2///62683#ACE405,0112/2///62683#ACE464,0112/2///62683#ACE406,0112/2///62683#ACE402,0112/2///62683#ACE407,0112/2///62683#ACE465,0112/2///62683#ACE408,0112/2///62683#ACE470,0112/2///62683#ACE409,0112/2///62683#ACE466,0112/2///62683#ACE425,0112/2///62683#ACE467,0112/2///62683#ACE427,0112/2///62683#ACE468,0112/2///62683#ACE428,0112/2///62683#ACE469,0112/2///62683#ACE739,0112/2///62683#ACE436,0112/2///62683#ACE437,0112/2///62683#ACE444,0112/2///62683#ACE447,0112/2///62683#ACE450,0112/2///62683#ACE451,0112/2///62683#ACE471,0112/2///62683#ACE445,0112/2///62683#ACE446,0112/2///62683#ACE449,0112/2///62683#ACE456,0112/2///62683#ACE461,0112/2///62683#ACE483}
MDC_P019
false
MDC_P033
{false}

Version history3#

  1. Current rev 01
    04 Jun 2025 · 22:40 UTC by BATCH 00000836
    View on cdd.iec.ch ↗
  2. superseded rev 01
    07 Jan 2020 · 21:31 UTC by BATCH 00000739
    ↓ Version JSON
    View on cdd.iec.ch ↗
  3. superseded rev 01
    16 Sep 2016 · 14:33 UTC by BATCH 00000703
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.