Control and auxiliary circuits
all the conductive parts of the device which are intended to be included in a circuit other than the main circuit
Hierarchy#
Ancestors (top) → ACC016 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes2#
Declared properties46#
maximum uninterrupted current equal to the conventional free-air thermal current (lth)
range of voltage combined with a rated operational current intended to be switched by the device under specified conditions
value of current at which the contact is intended to operate, under the conditions of utilization category AC-12
value of current at which the contact is intended to operate, under the conditions of utilization category AC-15, at a rated operational voltage of 230 V a.c.
value of current at which the contact is intended to operate, under the conditions of utilization category DC-13, at a rated operational voltage of 24 V d.c.
electrical ratings based on a rated conventional enclosed thermal current, a maximum operational voltage and AC utilization categories
electrical ratings based on a rated conventional enclosed thermal current, a maximum operational voltage and DC utilization categories
value of the minimum DC current associated with declared reliability data at which the low energy contact is intended to operate at the specified rated operational voltage
value of the DC voltage associated with declared reliability data at which the low energy contact is intended to operate at the specified rated operational current
number of contact elements, included in a control circuit or in an auxiliary circuit and mechanically operated by the switching device, which open when actuated
maximum number of contact elements, included in a control circuit or an auxiliary circuit and mechanically operated by the switching device or the actuator, available as options
number of contact elements, included in a control circuit or an auxiliary circuit and mechanically operated by the switching device or the actuator, which open with a delay when actuated
number of contact elements, included in a control circuit or an auxiliary circuit and mechanically operated by the switching device or the actuator, which close when actuated
maximum number of contact elements, included in a control circuit or an auxiliary circuit and mechanically operated by the switching device or the actuator, which close when actuated, available as options
number of contact elements, included in a control circuit or an auxiliary circuit and mechanically operated by the switching device or the actuator, which close before any normally open contact
number of contact element combinations included in a control circuit or an auxiliary circuit and mechanically operated by the switching device or the actuator, each combination including one make contact element and one break contact element
maximum number of contacts element combinations included in a control circuit or an auxiliary circuit and mechanically operated by the switching device or the actuator, available as options, each combination including one make contact element and one break contact element
type of driving a contact element of a control device in which the velocity of contact motion is dependent or not of the velocity of motion of the actuator
number of on-load operating cycles which will be attained or exceeded by 90 % of all devices tested, without repair or replacement of any part
number of contact elements which open when actuated
number of contact elements which close when actuated
number of contact element combinations, each combination including one make-contact element and one break contact element
time elapsed between the energisation of the motor operator and the closing of the main contacts of the device
time elapsed between the energisation of the motor operator and the opening of the main contacts of the device
ability to be a part of a safety control system used to implement a safety function
number of operating positions of the switch depending on the positions of the foot
range of supply voltage of a device including supply tolerances, from the lower limit to the upper limit
frequency of the supply assigned to a device by the manufacturer for a specified operating condition
range of current combined with an AC rated operational voltage intended to be switched by the device under specified conditions
range of current combined with a DC rated operational voltage intended to be switched by the device under specified conditions
the current which flows through the load circuit of the proximity switch in the OFF-state
minimum current necessary to maintain the ON-state conduction of the switching element
voltage measured across the switching element when carrying the operational current flow under specified conditions.
device output protected against overload and short-circuits of the connected load
value of current at which the contact is intended to operate, under the conditions of utilization category AC-14, at a rated operational voltage of 230 V a.c.
method of releasing the latching mechanism
current or voltage output signal which varies continuously depending on the sensing quantity
value of the power of a given type of lamp declared by the manufacturer or the responsible vendor, the lamp being operated under specified conditions
limits of the setting of the time delaying a control signal
direction of the front edge of the signal initiating the function
input signal used to initiate the function
kind of electric current supply
range of r.m.s. rated voltage at the frequency of 50 Hz applied to the control circuit or its supply
range of r.m.s. rated voltage at the frequency of 60 Hz applied to the control circuit or its supply
range of DC rated voltage applied to the control circuit or its supply
rated control supply voltage and current of the device compatible with the digital output characteristics of a PLC
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Instances (powertype)38#
ACG006Control and auxiliary circuitsACG017Control and auxiliary circuitsACG021Control and auxiliary circuitsACG040Control and auxiliary circuitsACG048Control and auxiliary circuitsACG064Control and auxiliary circuitsACG077Control and auxiliary circuitsACG098Current ratings of the assemblyACG103Control and auxiliary circuitsACG108Control and auxiliary circuitsACG113Control and auxiliary circuitsACG118Control and auxiliary circuitsACG123Control and auxiliary circuitsACG127Control and auxiliary circuitsACG130Control and auxiliary circuitsACG134Control and auxiliary circuitsACG139Control and auxiliary circuitsACG145Control and auxiliary circuitsACG151Control and auxiliary circuitsACG153Control and auxiliary circuitsACG159Control and auxiliary circuitsACG160Control and auxiliary circuitsACG183Main circuit (of a switching device)ACG213Control and auxiliary circuitsACG216Control and auxiliary circuitsACG219Control and auxiliary circuitsACG227Control and auxiliary circuitsACG239Control and auxiliary circuitsACG243Control and auxiliary circuitsACG248Control and auxiliary circuitsACG253Control and auxiliary circuitsACG262Control and auxiliary circuitsACG266Control and auxiliary circuitsACG270Control and auxiliary circuitsACG274Control and auxiliary circuitsACG289Control and auxiliary circuitsACG294Control and auxiliary circuitsACG302Control and auxiliary circuits
Metadata#
- Version
- 2
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 62683-1:2017
- Responsible committee
- IEC SC121A
- Change request
C00087- Dates
- Original: 2011-03-04
- Current version: 2022-06-17
- Current revision: 2022-06-17
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (33 keys from source .xls) — click to expand
- C002
- C00087
- C011
- IEC
- C012
- IEC 62683-1:2017
- C016
- Standard
- C017.de
- 1
- C017.fr
- 1
- C017.zh
- 1
- C018.de
- 2017-06-15
- C018.fr
- 2020-01-11
- C018.zh
- 2017-09-26
- C019.de
- DKE, Jürgen Schütz
- C019.fr
- IEC 121A/WG 17
- C019.zh
- SAC, Li Hui
- MDC_P001_5
- 0112/2///62683#ACC016
- MDC_P002_1
- 2
- MDC_P002_2
- 1
- MDC_P003_0
- 2020-01-11
- MDC_P003_1
- 2011-03-04
- MDC_P003_2
- 2022-06-17
- MDC_P003_3
- 2022-06-17
- MDC_P004.de
- Steuer- und Hilfsstromkreise
- MDC_P004.en
- Control and auxiliary circuits
- MDC_P004.fr
- Circuits de commande et auxiliaire
- MDC_P004.zh
- 控制和辅助电路
- MDC_P006.de
- alle leitfähigen Teile eines Schaltgeräts, die zu anderen Stromkreisen als dem Hauptstromkreis des Geräts gehören
- MDC_P006.en
- all the conductive parts of the device which are intended to be included in a circuit other than the main circuit
- MDC_P006.fr
- ensemble des pièces conductrices de l'appareil destinées à être insérées dans un circuit autre que le circuit principal
- MDC_P006.zh
- 在主电路之外的电路中使用的开关电器的所有导电部件。
- MDC_P010
- 0112/2///62683#ACC010
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC SC121A
- MDC_P014
- {0112/2///62683#ACE511,0112/2///62683#ACE512,0112/2///62683#ACE508,0112/2///62683#ACE509,0112/2///62683#ACE514,0112/2///62683#ACE515,0112/2///62683#ACE602,0112/2///62683#ACE604,0112/2///62683#ACE606,0112/2///62683#ACE521,0112/2///62683#ACE522,0112/2///62683#ACE601,0112/2///62683#ACE608,0112/2///62683#ACE455,0112/2///62683#ACE531,0112/2///62683#ACE532,0112/2///62683#ACE533,0112/2///62683#ACE534,0112/2///62683#ACE537,0112/2///62683#ACE538,0112/2///62683#ACE539,0112/2///62683#ACE540,0112/2///62683#ACE516,0112/2///62683#ACE518,0112/2///62683#ACE519,0112/2///62683#ACE520,0112/2///62683#ACE502,0112/2///62683#ACE503,0112/2///62683#ACE504,0112/2///62683#ACE505,0112/2///62683#ACE506,0112/2///62683#ACE507,0112/2///62683#ACE517,0112/2///62683#ACE513,0112/2///62683#ACE510,0112/2///62683#ACE501,0112/2///62683#ACE541,0112/2///62683#ACE424,0112/2///62683#ACE523,0112/2///62683#ACE544,0112/2///62683#ACE545,0112/2///62683#ACE546,0112/2///62683#ACE547,0112/2///62683#ACE524,0112/2///62683#ACE542,0112/2///62683#ACE548}
- MDC_P019
- false
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.