Service functions of the assembly
functions performed by the assembly in addition to its essential functions and capabilities
Hierarchy#
Ancestors (top) → ACG020 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties2#
code characterizing the levels of ability of the assembly to electrically separate or mechanically condemn all or part of its functional units with a view to their operation, repair and evolution
ability to provide annual energy consumption of the loads measured by usage
Imported properties2#
Imported property records not in browser data
Imported property references (entities not in browser data) (2)
- KEA306
- KEA302
These IRDIs appear in the source data but their full records weren't scraped.
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Is case of (powertype parents)1#
Powertype parent records not in browser data
Is-case-of references (entities not in browser data) (1)
- KEA012
These IRDIs appear in the source data but their full records weren't scraped.
Metadata#
- Note
- Typical essential functions and capability are switching loads, over-current protections and short-circuit withstand.
- Remark
- This block of properties should be reserved for those if no other appropriate properties are made available.
- Version
- 2
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 62683-2-2:2025
- Responsible committee
- IEC/TC 121
- Change request
C00184- Dates
- Original: 2022-08-03
- Current version: 2026-01-30
- Current revision: 2026-01-30
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (29 keys from source .xls) — click to expand
- C002
- C00184
- C011
- IEC
- C012
- IEC 62683-2-2:2025
- C016
- Standard
- C017.fr
- 1
- C018.fr
- 8/3/2022
- C019.fr
- IEC TC 121/WG 3
- MDC_P001_5
- 0112/2///62683#ACG020
- MDC_P002_1
- 2
- MDC_P002_2
- 1
- MDC_P003_0
- 2026-01-30
- MDC_P003_1
- 2022-08-03
- MDC_P003_2
- 2026-01-30
- MDC_P003_3
- 2026-01-30
- MDC_P004.en
- Service functions of the assembly
- MDC_P004.fr
- Fonctions de service de l'ensemble
- MDC_P006.en
- functions performed by the assembly in addition to its essential functions and capabilities
- MDC_P006.fr
- fonctions exercées par l'ensemble en plus de ses fonctions et capacités essentielles
- MDC_P008.en
- Typical essential functions and capability are switching loads, over-current protections and short-circuit withstand.
- MDC_P008.fr
- Les fonctions et capacités essentielles typiques sont la commutation de charges, les protections contre les surintensités et la tenue aux courts-circuits.
- MDC_P009.en
- This block of properties should be reserved for those if no other appropriate properties are made available.
- MDC_P009.fr
- Ce bloc de propriétés doit être réservé à celles qui ne disposent pas d'autres propriétés appropriées.
- MDC_P010
- 0112/2///62683#ACG000
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/TC 121
- MDC_P013
- {0112/2///63213#KEA012}
- MDC_P014
- {0112/2///62683#ACE264,0112/2///62683#ACE265}
- MDC_P019
- false
- MDC_P090
- {0112/2///63213#KEA306,0112/2///63213#KEA302}
Version history4#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.