Control and auxiliary circuits

0112/2///62683#ACG159

all the conductive parts of the coded magnetic switch which are intended to be included in a circuit other than the main circuit

Inherited
46

Hierarchy#

Ancestors (top) → ACG159 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties#

No declared properties

This class does not declare any properties of its own.

Inherited properties (46) — click to expand
ACE455rated operational voltageLEVEL(MIN,MAX) OF INT_MEASURE_TYPE

range of voltage combined with a rated operational current intended to be switched by the device under specified conditions

ACE534rated operational current, d.c.LEVEL(MIN,MAX) OF INT_MEASURE_TYPE

range of current combined with a DC rated operational voltage intended to be switched by the device under specified conditions

number of contact elements, included in a control circuit or an auxiliary circuit and mechanically operated by the switching device or the actuator, which close when actuated

number of contact element combinations included in a control circuit or an auxiliary circuit and mechanically operated by the switching device or the actuator, each combination including one make contact element and one break contact element

maximum number of contacts element combinations included in a control circuit or an auxiliary circuit and mechanically operated by the switching device or the actuator, available as options, each combination including one make contact element and one break contact element

ACE602rated control voltage, a.c., 50 HzLEVEL(MIN,MAX) OF INT_MEASURE_TYPE

range of r.m.s. rated voltage at the frequency of 50 Hz applied to the control circuit or its supply

ACE604rated control voltage, a.c., 60 HzLEVEL(MIN,MAX) OF INT_MEASURE_TYPE

range of r.m.s. rated voltage at the frequency of ­60 Hz applied to the control circuit or its supply

ACE606rated control voltage, d.c.LEVEL(MIN,MAX) OF INT_MEASURE_TYPE

range of DC rated voltage applied to the control circuit or its supply

ACE521motor-operator closing timeREAL_MEASURE_TYPE

time elapsed between the energisation of the motor operator and the closing of the main contacts of the device

ACE522motor-operator opening timeREAL_MEASURE_TYPE

time elapsed between the energisation of the motor operator and the opening of the main contacts of the device

ACE608compatible with PLC outputsENUM_BOOLEAN_TYPE

rated control supply voltage and current of the device compatible with the digital output characteristics of a PLC

ACE531supply voltage limitLEVEL(MIN,MAX) OF REAL_MEASURE_TYPE

range of supply voltage of a device including supply tolerances, from the lower limit to the upper limit

ACE532rated supply frequencyENUM_STRING_TYPE

frequency of the supply assigned to a device by the manufacturer for a specified operating condition

ACE533rated operational current, a.c.LEVEL(MIN,MAX) OF INT_MEASURE_TYPE

range of current combined with an AC rated operational voltage intended to be switched by the device under specified conditions

ACE537OFF-state currentREAL_MEASURE_TYPE

the current which flows through the load circuit of the proximity switch in the OFF-state

ACE538ON-state current, minimumLEVEL(MIN) OF REAL_MEASURE_TYPE

minimum current necessary to maintain the ON-state conduction of the switching element

ACE539voltage dropREAL_MEASURE_TYPE

voltage measured across the switching element when carrying the operational current flow under specified conditions.

ACE516contact element action typeENUM_STRING_TYPE

type of driving a contact element of a control device in which the velocity of contact motion is dependent or not of the velocity of motion of the actuator

number of contact element combinations, each combination including one make-contact element and one break contact element

value of current at which the contact is intended to operate, under the conditions of utilization category AC-15, at a rated operational voltage of 230 V a.c.

value of current at which the contact is intended to operate, under the conditions of utilization category DC-13, at a rated operational voltage of 24 V d.c.

electrical ratings based on a rated conventional enclosed thermal current, a maximum operational voltage and AC utilization categories

electrical ratings based on a rated conventional enclosed thermal current, a maximum operational voltage and DC utilization categories

number of on-load operating cycles which will be attained or exceeded by 90 % of all devices tested, without repair or replacement of any part

number of contact elements, included in a control circuit or an auxiliary circuit and mechanically operated by the switching device or the actuator, which close before any normally open contact

number of contact elements, included in a control circuit or an auxiliary circuit and mechanically operated by the switching device or the actuator, which open with a delay when actuated

ACE501rated operational current, AC-12REAL_MEASURE_TYPE

value of current at which the contact is intended to operate, under the conditions of utilization category AC-12

value of current at which the contact is intended to operate, under the conditions of utilization category AC-14, at a rated operational voltage of 230 V a.c.

ACE424rated currentLEVEL(MAX) OF REAL_MEASURE_TYPE

maximum uninterrupted current equal to the conventional free-air thermal current (lth)

ACE544type of analogue outputENUM_STRING_TYPE

current or voltage output signal which varies continuously depending on the sensing quantity

ACE545rated power (of a type of lamp)REAL_MEASURE_TYPE

value of the power of a given type of lamp declared by the manufacturer or the responsible vendor, the lamp being operated under specified conditions

ACE546time delay setting rangeLEVEL(MIN,MAX) OF REAL_MEASURE_TYPE

limits of the setting of the time delaying a control signal

ACE547triggering edgeENUM_STRING_TYPE

direction of the front edge of the signal initiating the function

ACE548triggering inputENUM_STRING_TYPE

input signal used to initiate the function

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Is case of (powertype parents)1#

Metadata#

Version
1
Revision
1
Status
Standard
Publisher
IEC
Published in
IEC 62683DB
Responsible committee
IEC/TC 121
Change request
C00107
Dates
  • Original: 2022-09-08
  • Current version: 2022-09-08
  • Current revision: 2022-09-08

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (34 keys from source .xls) — click to expand
C002
C00107
C011
IEC
C012
IEC 62683DB
C016
Standard
C017.de
1
C017.fr
1
C017.zh
1
C018.de
2022-08-16
C018.fr
11/24/20
C018.zh
2022-07-31
C019.de
DKE, Silvio Förtsch
C019.fr
IEC TC 121/WG 3
C019.zh
SAC,Jia Feng
MDC_P001_5
0112/2///62683#ACG159
MDC_P002_1
1
MDC_P002_2
1
MDC_P003_0
2022-09-08
MDC_P003_1
2022-09-08
MDC_P003_2
2022-09-08
MDC_P003_3
2022-09-08
MDC_P004.de
Steuer- und Hilfsstromkreise
MDC_P004.en
Control and auxiliary circuits
MDC_P004.fr
Circuits de commande et auxiliaire
MDC_P004.zh
控制和辅助电路
MDC_P006.de
alle leitenden Teile des kodierten Magnetschalters, die für die Verbindung mit einem Stromkreis, der kein Hauptstromkreis ist, vorgesehen sind
MDC_P006.en
all the conductive parts of the coded magnetic switch which are intended to be included in a circuit other than the main circuit
MDC_P006.fr
ensemble des pièces conductrices de l'interrupteur codé magnétique destinées à être insérées dans un circuit autre que le circuit principal
MDC_P006.zh
包括在主电路以外的电路中的编码磁性开关的所有导电部件
MDC_P010
0112/2///62683#ACG000
MDC_P011
ITEM_CLASS
MDC_P012
IEC/TC 121
MDC_P013
{0112/2///62683#ACC016}
MDC_P019
false
MDC_P090
{0112/2///62683#ACE518,0112/2///62683#ACE519,0112/2///62683#ACE455,0112/2///62683#ACE534}

Version history1#

  1. Current rev 01
    08 Sep 2022 · 13:54 UTC by BATCH 00000798
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.