Skip to content
OpenCDD
classITEM_CLASSv1rev 12021-08-26

Installation, mounting and dimensions

0112/2///63213#KEA011

physical information of the device for installation

Hierarchy#

Ancestors (top) → KEA011 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes2#

Declared properties7#

7 / 7
KEA321portable deviceENUM_STRING_TYPE

measuring instrument designed to be easily carried by hand and to be connected and disconnected by the user

KEA323number of modular spacingsENUM_STRING_TYPE

number of modular device snapped on DIN rails within distribution panel, whose front face is accessible without opening the panel

housing device snapped on DIN rails inside the distribution panel, whose front face is not accessible without opening the panel

KEA336max. height of the deviceREAL_MEASURE_TYPE

maximum height of the device, including fix connectors and pluggable connectors, and with the fixation space

KEA337max. width of the deviceREAL_MEASURE_TYPE

maximum width of the device, including fix connectors and pluggable connectors, and with the fixation space

KEA338max. depth of the deviceREAL_MEASURE_TYPE

maximum depth of the device, including fix connectors and pluggable connectors, and with the fixation space

Imported properties1#

Imported property records not in browser data

Imported property references (entities not in browser data) (1)

  • ACE808

These IRDIs appear in the source data but their full records weren't scraped.

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Is case of (powertype parents)1#

Powertype parent records not in browser data

Is-case-of references (entities not in browser data) (1)

  • ACC066

These IRDIs appear in the source data but their full records weren't scraped.

Metadata#

Version
1
Revision
1
Status
Standard
Publisher
IEC
Responsible committee
IEC/TC 85
Change request
C00103
Dates
  • Original: 2021-08-26
  • Current version: 2021-08-26
  • Current revision: 2021-08-26

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (32 keys from source .xls) — click to expand
C002
C00103
C011
IEC
C016
Standard
C017.de
1
C017.fr
1
C017.zh
1
C018.de
2018-08-07
C018.fr
2018-08-07
C018.zh
2018-08-07
C019.de
DKE
C019.fr
IEC/TC 85
C019.zh
SAC
MDC_P001_5
0112/2///63213#KEA011
MDC_P002_1
1
MDC_P002_2
1
MDC_P003_0
2021-08-27
MDC_P003_1
2021-08-26
MDC_P003_2
2021-08-26
MDC_P003_3
2021-08-26
MDC_P004.de
Installation, Einbau und Abmessungen
MDC_P004.en
Installation, mounting and dimensions
MDC_P004.fr
Installation, montage et dimensions
MDC_P004.zh
一般技术数据
MDC_P006.de
physikalische Geräte-Information für den Einbau
MDC_P006.en
physical information of the device for installation
MDC_P006.fr
informations physiques pour l’installation de l'appareil
MDC_P010
0112/2///63213#KEA010
MDC_P011
ITEM_CLASS
MDC_P012
IEC/TC 85
MDC_P013
{0112/2///62683#ACC066}
MDC_P014
{0112/2///63213#KEA336,0112/2///63213#KEA337,0112/2///63213#KEA338,0112/2///63213#KEA321,0112/2///63213#KEA322,0112/2///63213#KEA323,0112/2///63213#KEA324}
MDC_P090
{0112/2///62683#ACE808}

Version history1#

  1. Current rev 01
    27 Aug 2021 · 10:20 UTC by BATCH 00000918
    View on cdd.iec.ch ↗