Short-circuit
short-circuit conditions, stated by the manufacturer, which the device can make, withstand or break satisfactorily (specific to AC miniature circuit-breaker)
- Inherited
- 4
Hierarchy#
Ancestors (top) → KDE016 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties#
No declared properties
This class does not declare any properties of its own.
Inherited properties (4) — click to expand
value of ultimate short-circuit breaking capacity at 230 V AC assigned to that circuit-breaker by the manufacturer
value of ultimate short-circuit breaking capacity at 400 V AC assigned to that circuit-breaker by the manufacturer
class number (class 1 or class 3) defined by standard EN 60898-1 or EN 61009-1 as relevant
value of the AC limiting short-circuit making and breaking capacity on each individual protected pole of multipole circuit breakers
Imported properties8#
KDB004rated short-circuit capacity, AC, 230 V (Icn)KDB005rated short-circuit capacity, AC, 400 V (Icn)KDB006energy limiting class according to relevant EN standardKDB007rated making and breaking capacity of an individual pole, AC (Icn1)ACE701Not in dataACE702Not in dataACE715Not in dataACE716Not in data
Imported property references (entities not in browser data) (4)
- ACE701
- ACE702
- ACE715
- ACE716
These IRDIs appear in the source data but their full records weren't scraped.
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Is case of (powertype parents)1#
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 63508
- Responsible committee
- IEC/SC 23E
- Change request
C00138- Dates
- Original: 2025-10-15
- Current version: 2025-10-15
- Current revision: 2025-10-15
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (19 keys from source .xls) — click to expand
- C002
- C00138
- C011
- IEC
- C012
- IEC 63508
- C016
- Standard
- MDC_P001_5
- 0112/2///63508#KDE016
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2025-10-15
- MDC_P003_1
- 2025-10-15
- MDC_P003_2
- 2025-10-15
- MDC_P003_3
- 2025-10-15
- MDC_P004.en
- Short-circuit
- MDC_P006.en
- short-circuit conditions, stated by the manufacturer, which the device can make, withstand or break satisfactorily (specific to AC miniature circuit-breaker)
- MDC_P010
- 0112/2///63508#KDE005
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 23E
- MDC_P013
- {0112/2///63508#KDA222}
- MDC_P019
- false
- MDC_P090
- {0112/2///63508#KDB004,0112/2///63508#KDB005,0112/2///63508#KDB006,0112/2///63508#KDB007,0112/2///62683#ACE701,0112/2///62683#ACE702,0112/2///62683#ACE715,0112/2///62683#ACE716}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.