v1rev 42013-10-16IEC 60534-9
step response time T86
0112/2///61987#ABD714
interval of time between initiation of an input signal step change and the moment that the, response of a dynamic reaches 86,5 % of its full steady-state value
- Used by classes
- 2
- Code
ABD714- Data type
- REAL_MEASURE_TYPEmeasure
- Unit
- UAA972 UAA972
Version history4#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.
Metadata#
- Note
- The step response time includes the dead time before the dynamic response.
- Source document
- IEC 60534-9
- Version
- 1
- Revision
- 4
- Status
- Standard
- Change request
C00004- Dates
- Original: 2013-09-02
- Current version: 2013-10-16