Connection facilities
terminals, screws or other parts, used for the electrical connection of conductors of external circuits of the device
Hierarchy#
Ancestors (top) → ACC068 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes2#
Declared properties32#
the part(s) of the terminal necessary for the mechanical clamping and the electrical connection of the conductor(s), including the parts which are necessary to ensure the correct contact pressure
the part(s) of the terminal necessary for the mechanical clamping and the electrical connection of the conductor(s), including the parts which are necessary to ensure the correct contact pressure, second type integrated in the device
type of electrical connection of the main circuit of a device to the conductor suitable for the intended use
electrical connection and disconnection of a terminal can be performed without displacing the conductors of the corresponding circuit
type of electrical connection of auxiliary and/or control circuits of a device to the conductor suitable for the intended use
construction type enabling the device to be disconnected from the main circuit or to be removed
physical design of the electrical connection from the body of the sensor to the conductor suitable for the intended use
value of the length of the electrical connecting cable
unit which plugs into a rack and is supported by guides
material of the tubular covering of the cable
maximum cross-section expressed in AWG or kcmil size of all connectable types of conductors, rigid (solid and stranded) and flexible, stated by the manufacturer, and to which certain thermal, mechanical and electrical requirements are referred
value of the maximum cross-section of all connectable types of conductors, rigid (solid and stranded) and flexible, stated by the manufacturer, and to which certain thermal, mechanical and electrical requirements are referred
ACE863cross-section of flexible conductor in AWG or kcmil size, minimumENUM_CODE_TYPE(0112/2///61987#ABN524)minimum cross-sections of connectable flexible conductors in AWG or kcmil size, stated by the manufacturer, and to which some mechanical and electrical requirements are referred by the performed tests
ACE864cross-section of flexible conductor in AWG or kcmil size, maximumENUM_CODE_TYPE(0112/2///61987#ABN524)maximum cross-sections of connectable flexible conductors in AWG or kcmil size, stated by the manufacturer, and to which some mechanical and electrical requirements are referred by the performed tests
range of the cross-sections of connectable flexible conductors, stated by the manufacturer, and to which some mechanical and electrical requirements are referred by the performed tests
ACE866cross-section of rigid conductor in AWG or kcmil size, minimumENUM_CODE_TYPE(0112/2///61987#ABN524)minimum cross-sections of connectable rigid conductors in AWG or kcmil size, stated by the manufacturer, and to which some mechanical and electrical requirements are referred by the performed tests
range of the cross-sections of connectable rigid conductors, stated by the manufacturer, and to which some mechanical and electrical requirements are referred by the performed tests
orientation of the wire connection compared to the mounting surface of the device
orientation of the main circuit connections when the device is in preferred position of use
total number of clamping units supported by the terminal assembly
number of independent conductive paths of the device
number of openings in the housing necessary for the electrical connection
mechanical characteristic of the opening in the housing necessary for the electrical connection
ACE886cross-section of rigid conductor in AWG or kcmil size, maximumENUM_CODE_TYPE(0112/2///61987#ABN524)maximum cross-sections of connectable rigid conductors in AWG or kcmil size, stated by the manufacturer, and to which some mechanical and electrical requirements are referred by the performed tests
identification number of the conductor entry into the assembly
identification name of the conductor entry into the assembly
relative location of the part with openings which permit the passage of conductors into the assembly
dimension of the conductor entry from its reference point along axis "Z”
dimension of the conductor entry from its reference point along its axis "Y”
geometry of the of the part with openings which permit the passage of conductors into the assembly
dimension of the conductor entry from its reference point along its axis "X”
point of reference located at the extreme left (x axis), bottom (z axis) and rear (z axis) of the conductor entry
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Instances (powertype)24#
ACG009Connection facilitiesACG026Connection facilitiesACG043Connection facilitiesACG058Connection facilitiesACG093Cables entryACG094Busbar trunking system entryACG115Connection facilitiesACG124Connection facilitiesACG136Connection facilitiesACG141Connection facilitiesACG184Connection facilitiesACG189Connection facilitiesACG193Connection facilitiesACG197Connection facilitiesACG201Connection facilitiesACG214Connection facilitiesACG241Connection facilitiesACG250Connection facilitiesACG275Connection facilitiesACG296Connection facilitiesACG304Connection facilitiesACG316Connection facilities of side 1ACG317Connection facilities of side 2ACG318Connection facilities of the cable
Metadata#
- Version
- 3
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 62683-2-2:2025
- Responsible committee
- IEC/TC 121
- Change request
C00184- Dates
- Original: 2011-03-04
- Current version: 2026-01-30
- Current revision: 2026-01-30
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (33 keys from source .xls) — click to expand
- C002
- C00184
- C011
- IEC
- C012
- IEC 62683-2-2:2025
- C016
- Standard
- C017.de
- 1
- C017.fr
- 1
- C017.zh
- 1
- C018.de
- 6/15/2017
- C018.fr
- 9/16/2016
- C018.zh
- 9/26/2017
- C019.de
- DKE, Jürgen Schütz
- C019.fr
- IEC/TC 121/WG 3
- C019.zh
- SAC, Li Hui
- MDC_P001_5
- 0112/2///62683#ACC068
- MDC_P002_1
- 3
- MDC_P002_2
- 1
- MDC_P003_0
- 2026-01-30
- MDC_P003_1
- 2011-03-04
- MDC_P003_2
- 2026-01-30
- MDC_P003_3
- 2026-01-30
- MDC_P004.de
- Anschlussmöglichkeiten
- MDC_P004.en
- Connection facilities
- MDC_P004.fr
- Eléments de raccordement
- MDC_P004.zh
- 连接件
- MDC_P006.de
- Anschlüsse, Schrauben oder andere Teile, die für die elektrische Verbindung der Leitungen von externen Schaltkreisen verwendet werden
- MDC_P006.en
- terminals, screws or other parts, used for the electrical connection of conductors of external circuits of the device
- MDC_P006.fr
- bornes, vis et autres pièces, utilisées pour le raccordement électrique aux conducteurs des circuits externes de l'appareil
- MDC_P006.zh
- 用于与外部电路导体进行电气连接的连接端子、螺钉或其他部件。
- MDC_P010
- 0112/2///62683#ACC010
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/TC 121
- MDC_P014
- {0112/2///62683#ACE850,0112/2///62683#ACE851,0112/2///62683#ACE852,0112/2///62683#ACE853,0112/2///62683#ACE854,0112/2///62683#ACE855,0112/2///62683#ACE856,0112/2///62683#ACE857,0112/2///62683#ACE858,0112/2///62683#ACE859,0112/2///62683#ACE861,0112/2///62683#ACE862,0112/2///62683#ACE863,0112/2///62683#ACE864,0112/2///62683#ACE865,0112/2///62683#ACE866,0112/2///62683#ACE867,0112/2///62683#ACE869,0112/2///62683#ACE870,0112/2///62683#ACE872,0112/2///62683#ACE874,0112/2///62683#ACE875,0112/2///62683#ACE876,0112/2///62683#ACE886,0112/2///62683#ACE887,0112/2///62683#ACE888,0112/2///62683#ACF095,0112/2///62683#ACE894,0112/2///62683#ACE895,0112/2///62683#ACE896,0112/2///62683#ACE897,0112/2///62683#ACE898}
- MDC_P019
- false
Version history4#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.