Skip to content
OpenCDD
classITEM_CLASSv1rev 22013-07-29

Short-circuit rating

0112/2///62683#ACG024

prospective short-circuit condition, stated by the manufacturer, which the switch-disconnector can withstand satisfactorily

Inherited
25

Hierarchy#

Ancestors (top) → ACG024 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties#

No declared properties

This class does not declare any properties of its own.

Inherited properties (25) — click to expand

value of prospective current that a circuit or a switching device, protected by a short-circuit protective device, can satisfactorily withstand for the operating time of this device at the given rated operational voltage of 230 V

value of prospective current that a circuit or a switching device, protected by a short-circuit protective device, can satisfactorily withstand for the operating time of this device at the given rated operational voltage of 400 V

value of prospective current that a circuit or a switching device, protected by a short-circuit protective device, can satisfactorily withstand for the operating time of this device at the given rated operational voltage of 690 V

short-circuit making capacity assigned to an equipment for the rated operational voltage of 230 V, at rated frequency and at a specified power-factor, expressed as the maximum prospective peak current, under prescribed conditions

short-circuit making capacity assigned to an equipment for the rated operational voltage of 400 V, at rated frequency and at a specified power-factor, expressed as the maximum prospective peak current, under prescribed conditions

short-circuit making capacity assigned to an equipment for the rated operational voltage of 690 V, at rated frequency and at a specified power-factor, expressed as the maximum prospective peak current, under prescribed conditions

value of the prospective breaking current for the rated operational voltage of 230 V a.c., for which a specified test sequence do not include the capability of the circuit-breaker to carry its rated current continuously

value of the prospective breaking current at a rated operational voltage of 400 V a.c., for which a specified test sequence does not include the capability of the circuit-breaker to carry its rated current continuously

value of the prospective breaking current for the rated operational voltage of 690 V a.c., for which a specified test sequence do not include the capability of the circuit-breaker to carry its rated current continuously

value of the breaking capacity for the rated operational voltage of 230 V a.c., for which a specified test sequence includes the capability of the circuit-breaker to carry its rated current continuously, corresponding to one of the specified percentages of the rated ultimate short-circuit breaking capacity

value of the breaking capacity at a rated operational voltage of 400 V a.c., for which a specified test sequence includes the capability of the circuit-breaker to carry its rated current continuously, corresponding to one of the specified percentages of the rated ultimate short-circuit breaking capacity

value of the breaking capacity for the rated operational voltage of 690 V a.c, for which a specified test sequence includes the capability of the circuit-breaker to carry its rated current continuously, corresponding to one of the specified percentages of the rated ultimate short-circuit breaking capacity

ACE700interrupting rating, a.c., 120 VREAL_MEASURE_TYPE

the highest RMS symmetrical current at a rated voltage of 120 V a.c. that a device is intended to interrupt under standard test conditions

ACE703interrupting rating, a.c., 480 VREAL_MEASURE_TYPE

the highest RMS symmetrical current at a rated voltage of 480 V a.c. that a device is intended to interrupt under standard test conditions

ACE704interrupting rating, a.c., 600 VREAL_MEASURE_TYPE

the highest RMS symmetrical current at a rated voltage of 600 V a.c. that a device is intended to interrupt under standard test conditions

value of prospective current that a circuit or a switching device, protected by a short-circuit protective device, can satisfactorily withstand for the operating time of this device; type 2: under short-circuit conditions, the contactor or starter shall be suitable for further use; at the given rated operational voltage of 400 V a.c.

value of prospective current that a circuit or a switching device, protected by a short-circuit protective device, can satisfactorily withstand for the operating time of this device; type 2: under short-circuit conditions, the contactor or starter shall be suitable for further use at the given rated operational voltage of 230 V a.c.

value of prospective current that a circuit or a switching device, protected by a short-circuit protective device, can satisfactorily withstand for the operating time of this device; type 1: under short-circuit conditions, the contactor or starter shall cause no danger to persons or installation and may not be suitable for further service without repair and replacement of parts at the given rated operational voltage of 480 Y/277 V

value of prospective current that a circuit or a switching device, protected by a short-circuit protective device, can satisfactorily withstand for the operating time of this device; type 1: under short-circuit conditions, the contactor or starter shall cause no danger to persons or installation and may not be suitable for further service without repair and replacement of parts at the given rated operational voltage of 600 Y/347 V

ACE711rated peak withstand currentREAL_MEASURE_TYPE

value of peak short-circuit current declared by the assembly manufacturer, that can be withstood under specified conditions

value of the prospective short-circuit current, declared by the assembly manufacturer, that can be withstood for the total operating time (clearing time) of the short-circuit protective device under specified conditions

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Is case of (powertype parents)1#

Metadata#

Version
1
Revision
2
Status
Standard
Publisher
IEC
Published in
IEC 62683DB
Responsible committee
IEC SC121A
Change request
C00058
Dates
  • Original: 2013-07-29
  • Current version: 2013-07-29
  • Current revision: 2016-09-20

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (33 keys from source .xls) — click to expand
C002
C00058
C011
IEC
C012
IEC 62683DB
C016
Standard
C017.de
1
C017.fr
1
C017.zh
1
C018.de
2017-11-29
C018.fr
2016-03-29
C018.zh
2017-09-26
C019.de
DKE, Andreas Boeumler
C019.fr
IEC 121A/WG 17
C019.zh
SAC, Li Hui
MDC_P001_5
0112/2///62683#ACG024
MDC_P002_1
1
MDC_P002_2
2
MDC_P003_0
2020-01-07
MDC_P003_1
2013-07-29
MDC_P003_2
2013-07-29
MDC_P003_3
2016-09-20
MDC_P004.de
Kurzschlussbemessung
MDC_P004.en
Short-circuit rating
MDC_P004.fr
Valeur assignée de court-circuit
MDC_P004.zh
短路额定值
MDC_P006.de
Prospektive Kurzschlussbedingung, welcher der Lasttrennschalter nach Angaben des Herstellers ausreichend widerstehen kann
MDC_P006.en
prospective short-circuit condition, stated by the manufacturer, which the switch-disconnector can withstand satisfactorily
MDC_P006.fr
condition de court-circuit présumé, déclarée par le constructeur, que l'interrupteur-sectionneur peut supporter de façon satisfaisante
MDC_P006.zh
制造商规定的,隔离开关能够可靠耐受的预期短路条件。
MDC_P010
0112/2///62683#ACG000
MDC_P011
ITEM_CLASS
MDC_P012
IEC SC121A
MDC_P013
{0112/2///62683#ACC040}
MDC_P090
{0112/2///62683#ACE712,0112/2///62683#ACE722,0112/2///62683#ACE708,0112/2///62683#ACE723,0112/2///62683#ACE724,0112/2///62683#ACE725,0112/2///62683#ACE726}

Version history3#

  1. Current rev 02
    07 Jan 2020 · 21:31 UTC by BATCH 00000739
    View on cdd.iec.ch ↗
  2. superseded rev 02
    20 Sep 2016 · 10:24 UTC by BATCH 00000705
    ↓ Version JSON
    View on cdd.iec.ch ↗
  3. superseded rev 01
    16 Sep 2016 · 14:33 UTC by BATCH 00000703
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.